P26 MULTISPAN
Defines the calibration result to be used for subsequent measurements. Range = 0 to 8.
This feature may be used to store the Span calibration results associated with different operating conditions,
(e.g. change in conveyor incline, when an incline compensator is not utilized).
To perform a Span calibration for a specific operating condition:
a)Select the Multispan number to be associated with the current operating condition.
b)Enter the Test Reference value (P7) for the Test Reference selected (P20).
c)Perform a Zero and Span calibration. (If a Zero was performed recently, just perform a Span).
d) Perform a Span Adjust (P8) or Factoring (P9), as required.
To recall the calibration result (when the associated operating condition is re-encountered), select the
appropriate Multispan number. The MultiSpan number may be selected by providing one or more temporary or
permanent closed contacts between the TB1 COM (e.g. TB1-37) and the following TB1 terminals:
O = contact open
C = contact closed
For convenience, the Multispan number selection may be provided by a BCD switch connected to the
appropriate TB1-38,39,40,41, and COM contacts.
Alternatively, the Multispan number may be selected via the keypad. If "0" is entered, the MULTISPAN field of
the display is blank and Multispan 1 is utilized.
enter: desired value, (TB1-38,39,40, and 41 contacts must be open), (F=0).
P30 CALIBRATION DURATION (Belt Revolutions)
Defines the number of belt revolutions used for Zero and Span calibrations, Factoring (P9), and for Verification
Totalizer (P31) operation. Range = 0.01 to 99, (decimal values may not be used for verification totalizer
operation.
A low value reduces calibration time, while a high value increases calibration accuracy.
enter: desired value, (F = 1)
93/12/01
MULTISPAN TB1 TERMINALS CONNECTED TO COM
NUMBER41403938
1 OOOC
2OOCO
3OOCC
4OCOO
5OCOC
6OCCO
7 OCCC
8 COOO
PL-367 7 – 8