APPLICATIONS
The transducer is to be used only in the manner outlined in this instruction manual.
Normally, the transducer requires no cleaning or maintenance. However, if performance
changes are observed, immediately shut down the level measurement system and perform a
thorough inspection, especially on the transducer.
LIQUID APPLICATIONS - STILLING WELL / OCM
blind flange
air vent
TS-3 *
transducer
standpipe
bracing
standpipe inlet
stilling well
primary element
stilling well inlet
Refer to Liquid \ Applications - Standpipes.
*
the use of a TS-3 temperature sensor provides better temperature tracking
in applications where the temperature can change quickly.
PL-521 11